PUBLIC FLEET PROCUREMENT
Define the first fleet for a fire station
The first fleet for a station should reflect its response area, water sources, crew and approved equipment. Start with the incident risks and access routes, then divide the work between water delivery, firefighting equipment and rescue support. A coordinated mix is easier to operate and maintain than several vehicles selected only by tank capacity.

Define the roles before setting quantities
| Station role | Information needed | Specification focus |
|---|---|---|
| Initial water response | Response area, crew, refill points and expected pump duty | Tank capacity, pump performance, hose equipment and crew accommodation |
| Additional water supply | Distance to refill, road access and replenishment method | Usable water load, fill and discharge arrangements, chassis and axle loading |
| Foam application | Risk assessment, agent selected by the service and required system | Separate agent capacity, proportioning equipment and compatibility documentation |
| Rescue and scene support | Approved tool inventory, staffing and incident-support duties | Compartments, equipment retention, lighting, power and working access |
Review the whole water-supply cycle
An adequate tank is only one part of the response. Map the refill sources, expected travel time and available filling connections. State the pump operating point required by the service and the equipment that must be carried at the same time. Water, crew, tools and optional equipment all contribute to the vehicle's loaded mass.
Where narrow roads, gates or station bays constrain access, provide measurements and turning information with the enquiry. The proposed chassis should be checked against these constraints before the body and compartment layout is finalised.
Make equipment allocation visible
Create a compartment-by-compartment inventory for hoses, fittings, tools, protective equipment and other items in the supply scope. Identify buyer-supplied equipment separately. For powered tools or auxiliary lighting, specify the required electrical interfaces and operational expectations. This allows the offered arrangement to be reviewed without relying on a generic photograph.
Agree a demonstration and handover schedule
The acceptance plan can include vehicle identification, inventory checks, an agreed pump demonstration and operation of the supplied auxiliary equipment. State the test conditions and records required in the contract. Operator training should address the actual controls and equipment fitted to the delivered vehicle.
Chengli manufactures firefighting vehicles and supports batch dispatch from its specialist-vehicle facilities. For your station, we develop the proposal around a named model, its confirmed configuration and the inspection evidence required by the tender.
Illustrative fire station starter fleet architecture
Whether equipping a new district fire post or upgrading a municipal headquarters, balancing rapid first-out agility with sustained water and Class B foam capacity prevents operational gaps.
| Station role | Recommended apparatus | Tank & drive class | Primary incident duty |
|---|---|---|---|
| Rapid first-out urban response | Light water tanker fire truck | 2,000–4,500 L (4x2 / 4x4) | Dense markets, narrow streets, immediate structural knockdown |
| Primary municipal pumper-tanker | Medium water tanker fire truck | 4,800–8,000 L (4x2) | Residential, commercial and urban-rural response without hydrants |
| Fuel station & industrial protection | Water & foam fire truck | 5,000–12,000 L dual tank | Hydrocarbon spills, fuel depots, industrial zones and ports |
| Bulk water shuttle / relay | Heavy water tanker fire truck | 12,000–25,000 L (6x4 / 8x4) | Sustained water supply to first-out pumpers in hydrant-free zones |
Published fire apparatus models for municipal tenders
The models below are published in our current catalog with manufacturer specifications and can be used as baseline references when preparing tender technical schedules or requesting formal quotations:
| Model code | Vehicle role | Key listed parameters | Specification page |
|---|---|---|---|
| CLW5060GXFSG20 | JMC 4x2 Water Tanker Fire Truck (2,000 L) | 4x2 | 6,255 kg GVW | 2,000 L water | View specifications |
| CLW5110GXFSG50 | Dongfeng 4x2 Water Tanker Fire Truck (4.8 m³) | 4x2 | 4,800 L water | urban first-out | View specifications |
| CLW5280GXFSG120 | Sinotruk 6x4 Water Tanker Fire Truck (12 m³) | 6x4 | 12,000 L water | high-volume relay | View specifications |
| CLW5170GXFPM50 | 4x2 Water & Foam Fire Truck (5.1 m³) | 4x2 | dual water/foam tank | municipal & depot | View specifications |
| CLW5200GXFPM100 | 6x4 Industrial Foam Fire Truck | 6x4 | heavy water/foam split | ports & refineries | View specifications |
Fire station starter fleet FAQs
Should a new district fire station buy a pure water tanker or a water-foam truck?
If the district has fuel stations, highway fuel-tanker traffic or industrial storage, specifying a dual water-foam truck (with a 316L stainless steel foam tank) protects against both Class A and Class B fires; purely residential or rural water-relay roles achieve maximum water volume per budget dollar with a water tanker.
Is loose firefighting equipment included with the fire truck?
Basic suction hoses and standard accessories are listed per model; full loose equipment packages (SCBA sets, ladders, nozzles, hydraulic rescue tools) are itemised against your tender BoQ.
What factory acceptance tests (FAT) are conducted before shipment?
Pump priming, discharge pressure/flow, monitor operation, tank leak checks and electrical lighting tests can be witnessed via video or on-site inspection at the Suizhou factory (including buyer-arranged SGS/BV).
Vehicle models to compare

Patient Transport Ambulance CLW5030XJHCDP
The CLW5030XJHCDP is a patient transport ambulance built by Chengli Automobile Group for ministries of health, public hospitals and humanitarian NGOs. Its manufacturer record lists a 3,300 kg GVW class and 162 kW engine output. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.

Patient Transport Ambulance CL5030XJH6AYS
The CL5030XJH6AYS is a 4x2 patient transport ambulance built by Chengli Automobile Group for ministries of health, public hospitals and humanitarian NGOs. Its manufacturer record lists a 2,900 kg GVW class and 186.4 kW engine output. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.

Dust Suppression Truck CL5310TDYZ6YC
The CL5310TDYZ6YC is a 8x4 Sinotruk-chassis dust suppression truck built by Chengli Automobile Group for city councils, municipal sanitation departments and public-works contractors. Its manufacturer record lists a 21 m³ key specification, a 31,000 kg GVW class and 257 kW engine output. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.

Refuse Compactor CLW5250ZYSAHJ
The CLW5250ZYSAHJ is a 6x4 refuse compactor built by Chengli Automobile Group for city councils, municipal sanitation departments and public-works contractors. Its manufacturer record lists a 20–23 m³ key specification and a 25,000 kg GVW class. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.

Foam Fire Truck CLW5190GXFPM50
The CLW5190GXFPM50 is a 4x2 foam fire truck built by Chengli Automobile Group for municipal fire brigades, civil defence agencies and industrial safety fleets. Its manufacturer record lists a 19,100 kg GVW class and 149.1 kW engine output. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.

Washing-Sweeping Truck CLW5080TXSJ6
The CLW5080TXSJ6 is a 4x2 JMC-chassis washing-sweeping truck built by Chengli Automobile Group for city councils, municipal sanitation departments and public-works contractors. Its manufacturer record lists a 3 m cleaning width key specification, the JX1083TK26 chassis and a 8,210 kg GVW class. Right-hand-drive availability, final equipment fit-out and export documentation are confirmed per contract for government and donor-funded tenders.
TECHNICAL DOCUMENT REQUEST
Get the specification conversation started
Tell us your destination and vehicle requirement. PDF availability and the specification scope will be confirmed for the proposed model.